          Assay range30 nmol/L -800 nmol/L                      96 determinations

          Purpose

          This kit allows for the determination of Vitamin DVD concentrations in Human serum, cell culture supernates and other biological fluids

           

          Principle of the assay

          The kit assay Human Vitamin DVD level in the sampleuse Purified Human Vitamin DVD antibody to coat microtiter plate wells, make solid-phase antibody, then add Human Vitamin DVD to wells, Combined antibody which With HRP labeled goat anti- Human become antibody - antigen - enzyme-antibody complex, after washing Compley, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of  Human Vitamin DVD in the samples is then determined by comparing the O.D. of the samples to the standard curve.

          Materials provided with the kit

          1

          wash  solution

          20ml×1bottle

          7

          Stopp Solution

          6ml×1 bottle

          2

          HRP-Conjugate reagent

          6ml×1 bottle

          8

          Standard1600 nmol/L

          0.5ml×1 bottle

          3

          Microelisa stripplate

          12well×8strips

          9

          Standard diluent

          1.5ml×1bottle

          4

          Sample diluent

          6ml×1 bottle

          10

          Instruction

          1

          5

          Chromogen Solution A

          6ml×1 bottle

          11

          Closure plate membrane

          2

          6

          Chromogen Solution B

          6ml×1 bottle

          12

          Sealed bags

          1

          Specimen requirements

          1.       extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20 to preserve, Avoid repeated freeze-thaw cycles.

          2.       Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

          Assay procedure

          1.       Dilute and add sample:Dilute Original density Standard as follow table:

          800 nmol/L

          5 Standard

          150μl Original density Standard+150μl Standard diluent

          400 nmol/L

          4 Standard

          150μl 5 Standard+150μl Standard diluent

          200 nmol/L

          3 Standard

          150μl 4 Standard+150μl Standard diluent

          100 nmol/L

          2 Standard

          150μl 3 Standard +150μl Standard diluent

          50 nmol/L

          1 Standard

          150μl 2 Standard +150μl Standard diluent

          2.add sampleSet blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.

          3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37.

          4.Configurate liquid: 30-fold wash solution diluted 30-fold (or 20-fold) with distilled water and reserve.

          5.washingUncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.

          6.add enzymeAdd HRP-Conjugate reagent 50μl to each well, except  blank well.

          7.incubateOperation with 3.

          8.washingOperation with 5.

          9.colorAdd Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37

          10.Stop the reactionAdd Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).

          11.assaytake blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.

          Steps description

          Standard, Sample diluent

           

          Add Standard, Sample diluent, incubate for 30 min at 37.

           

          Wash 5 time,Add HRP-Conjugate reagent, incubate for 30 min at 37.

           

          Wash 5 times,Add Chromogen Solution A and B, incubate for 30 min at 37.

           

          Add Stopp Solution

           

          Read absorbance at 450nm within 15 min

           

          calculate

          Calculate

          Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor, the result is the sample actual density.

          Important notes

          1.       The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.

          2.       washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.

          3.       add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .

          4.       if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.×n×5.

          5.       Closure plate membrane only limits the disposable use, to avoid cross-contamination.

          6.       The substrate evade the light preservation.

          7.       Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.

          8.       All samples, washing buffer and each kind of reject should according to infective material process.

          9.       Do not mix reagents with those from other lots.

           

          Storage and validity

          1Storage  2-8.

          2validity six months.

           

          分享到:
          www.日韩三级www.日日爱| 免费精品国偷自产在线在线| 精品一区二区无码AV| 亚洲综合日韩中文字幕v在线| 精品人妻少妇一区二区三区不卡| 久久久久se色偷偷亚洲精品av| 亚洲嫩草影院久久精品| 国产精品乱码高清在线观看 | 国产成人亚洲精品91专区手机| 日韩大片免费观看视频播放| 好男人视频社区精品免费| 麻豆精品在线播放| 亚拍精品一区二区三区| 精品无码久久久久久尤物| 无码欧精品亚洲日韩一区| 亚洲国产成人精品无码区在线观看| 国产日韩精品SUV| 久久亚洲中文字幕精品一区四| 国产精品嫩草影院一二三区| 影院无码人妻精品一区二区| 日韩免费高清视频| 国产日韩一区二区三区在线播放| 日韩大片高清播放器| 亚洲午夜日韩高清一区| 日韩无码系列综合区| 四虎永久在线精品影院| 日韩高清在线二区| 日韩电影免费观看| 国产精品麻豆欧美日韩WW | 老司机性色福利精品视频| 久久99精品久久久久久青青日本| 国产精品视频色拍拍| 久久精品综合电影| 久久久亚洲精品国产| 麻豆成人久久精品二区三区免费| 无码精品国产VA在线观看| 99精品久久99久久久久| 亚洲欧洲精品久久| 国产精品乳摇在线播放| 色综合99久久久无码国产精品 | 日韩毛片无码永久免费看|